Call 08048262123 60% Response Rate

Send Email

Rapid Test Accessories

We are a leading Manufacturer of rapid diagnostic kits, plastic backing card for immunoassay card, pvc backing roll for rapid test, nitrocellulose membrane for lateral flow immunoassay, absorbent pad for rapid diagnostic kits and sample release pad sheet / roll from Vadodara, India.

Rapid Diagnostic Kits

Rapid Diagnostic Kits
  • Rapid Diagnostic Kits
  • Rapid Diagnostic Kits
Get Best Quote
Product Price: Rs 15 / UnitGet Best Price

Product Brochure

Product Details:
ICMR ApprovedYes
Sample TypeBlood
BrandPrahas
Tests KitRapid Test Kit
TypeCellulose
MaterialFiber
Time To Result10 min
Usage/ApplicationLaboratory
Packaging SizeSheet

Description:

The sample pad  can be used to perform multiple tasks, foremost of which is to promote the even and controlled distribution of the sample onto the conjugate pad. It may also control the rate at which liquid enters the conjugate pad, preventing flooding of the device. When impregnated with components such as proteins, detergents, viscosity enhancers, and buffer salts, the sample pad can also be used to:

  1. Increase sample viscosity (modulate flow properties).
  2. Enhance the ability of the sample to solubilize the detector reagent.
  3. Prevent the conjugate and analyte from binding non-specifically to any of the downstream materials.
  4. Modify the chemical nature of the sample so that it is compatible with immunocomplex formation at the test line.
  5. Promote even flow of the sample along the membrane.

The presence of added protein (such as albumin) and detergents and surfactants (such as SDS or TWEEN 20 at a very low concentration) may promote resolubilization of the conjugate, reduce nonspecific binding of the conjugate, and possibly minimize adsorption of the analyte to the membrane.

There are two types of materials that are commonly used as sample pads: cellulose fiber filters and woven meshes.

Woven meshes, sometimes called screens, normally work very well to distribute the sample volume evenly over the conjugate pad. They also typically have good tensile strength and handle well, even when wet. Meshes have very low bed volumes, meaning that they retain very little sample volume, normally 1 2 L/ cm2. On the other hand, it is impractical to treat them with the intention of loading them with enough solutes to modify the protein content, pH, ionic strength or viscosity of the test sample. Meshes can also be expensive relative to other porous media and difficult to process through strip cutting machinery.

 

Cellulose filters have properties that are nearly the opposite of woven meshes. They are thick (> 250 m), weak, and relatively inexpensive. Cellulose filters also have large bed volumes (> 25 L/ cm2). Paper can be very difficult to handle, especially when wet. Cellulosic filters are the most commonly used materials to make the sample pad because they can be loaded with a wide array of blocking agents, detector reagent release agents, pH and ionic strength modifiers, and viscosity enhancers. When using cellulose filters, care must be taken to ensure sufficient and consistent contact with the underlying conjugate pad material. Failure to achieve good contact and adequate compression can lead to interrupted or inconsistent transfer of fluid into the conjugate pad.



Additional Information:

  • Item Code: SP1
Yes! I am InterestedRequest A Callback

Plastic Backing Card For Immunoassay Card

Plastic Backing Card For Immunoassay Card
  • Plastic Backing Card For Immunoassay Card
  • Plastic Backing Card For Immunoassay Card
  • Plastic Backing Card For Immunoassay Card
Get Best Quote
Product Price: Rs 25 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Card TypeDiscount Cards
DesignPrinted
Surface FinishingMatte
MaterialPVC
ColorWhite
ShapeRectangle
BrandPrahas
Size85mm
FeaturesDurability
Country of OriginMade in India


Plastic Backing sheet /Cards available for Rapid immunoassay / Glucoassay / urine strip

Size customised and standard at best rates available 

Thickness : 200/250/300/400 micron
Adhesive : Regular / High gumming 
  

Additional Information:

  • Item Code: PVC
  • Production Capacity: 100000 Mtrs
  • Delivery Time: 2-4 weeks
Yes! I am InterestedRequest A Callback

PVC Backing Roll for Rapid Test

PVC Backing Roll for Rapid Test
Get Best Quote
Product Price: Rs 23 / MeterGet Best Price

Product Brochure

Product Details:
Usage/ApplicationPackaging
ColorTransparent
Length50 m
Packaging TypePacket
BrandPrahas
Country of OriginMade in India
MaterialPVC

Description

Product NamePVC Backing Roll for Rapid Test
CatalogPRHRMC007
AppearanceOff White
Dimension  WidthAs per Customer requirement
Slitting DimensionsAs per Customer requirement
Slitting line StraightnessStraight no curve
Length100 Mtr


AdhesiveSynthethic Acrylic
Adhesive strength Initial> 3# ball
Adhesive strength Endurance> 30 h

 



Additional Information:

  • Delivery Time: 7 days
Yes! I am InterestedRequest A Callback

Nitrocellulose Membrane For Lateral Flow Immunoassay

Nitrocellulose Membrane For Lateral Flow Immunoassay
Get Best Quote
Product Price: Rs 70 / PieceGet Best Price

Product Brochure

Product Details:
Tests KitLINE PRINTING TEST
TypeIMMUNO ASSEY
Usage/ApplicationClinical
MaterialPlastic
Cut OffMEDIUM
Measuring Time80-100
Length100MM
Height20MM
ColorWHITE
Packaging SizeAS PER YOU REQUIREMENT
Country of OriginMade in India
Nitrocelluloset membrane is a very critical component of the assey. Along with high protein binding, surface quality and performance consistency and crucial parameters of suubstrate quality.
variation in capillary flow rate and thikness across strip will be detrimental to a assey's sensitivity, reproducibility and reagent consumptions. in case of uneven fiber distribution or nitrocellulose powder settlements on the surface, the protein binding ability of the membrane wiil be compromised. Further, variations in the mentioned parameters across batches can create issues of manufacturing in process approvals and final assey performance.
we provides consistent, reliable membrane with best surface quality and performance consistency to improve your assey.
strong in house capabilites including customised casting machines, large batch size, proprietary processes,strict process controls and stringent product testing standards enable us to provide yu the membrane which is consistent in physical and chemical properties.

Key Properties:
1. High protein binding: small pore size allows for higher protein binding capacity of the membrane.
2. Consistent thikness: allows homogeneous membrane structure and in-turn uniform protein binding.
3. Surface quality: smoth, powder free surface with low background signal allows for sharp capture line and clear results to maximize sensitivity and specificity of the test.
4. Hydrophilic: surfactant is added for fast wetting 
5. Consistent properties: specially-designed & custome-built production lines to ensure intra and intra-lot consistency aiding test sensitivity throughout your product's life-cycle.
6: Purity: constructed of 100% pure nitrocellulose polymer that contains no interfering contaminant or post-treatment chemicals that affect assey performance.
USED FOR: PREGNENCY TEST

Additional Information:

  • Item Code: PHC90
  • Delivery Time: 20 DAYS
  • Packaging Details: AS PER YOUR REQUIREMNT
Yes! I am InterestedRequest A Callback

Absorbent Pad for Rapid Diagnostic Kits

Absorbent Pad for Rapid Diagnostic Kits
  • Absorbent Pad for Rapid Diagnostic Kits
  • Absorbent Pad for Rapid Diagnostic Kits
  • Absorbent Pad for Rapid Diagnostic Kits
Get Best Quote
Product Price: Rs 5 / PieceGet Best Price

Minimum Order Quantity: 50 Piece

Product Brochure

Product Details:
ICMR ApprovedYes
BrandPrahas
Tests KitRapid Test Kit
Usage/ApplicationHospital
MaterialCellulose
Sample TypeBlood
ColorWhite
Country of OriginMade in India
Packaging TypeRoll

Description:

Absorbent pads, when used, are placed at the distal end of the test strip (Figure ). The primary function of the absorbent pad is to increase the total volume of sample that enters the test strip. This increased volume can be used to wash unbound detector particles away from the test and control lines, thereby lowering the background and enhancing assay sensitivity. Since the volume of sample that ultimately contributes to signal is controlled by the volume required to solubilize the detector particles, and not by the total volume of sample that enters the device, the addition of the absorbent pad may not have a dramatic impact on overall assay sensitivity. If the strip design does not include an absorbent pad, the volume of sample analyzed in the strip is determined solely by the bed volume of the membrane.

Figure 4

 

There are two major considerations associated with the use of absorbent pads. First, a suitable material must be identified, specified, purchased, and integrated into the manufacturing process. Ultimately, this leads to a higher cost for the finished product. Second, an absorbent pad makes it difficult to incorporate an end-of-assay indicator in the test device. The flow of liquid through the absorbent pad is not necessarily laminar, and the pad may fill with liquid unpredictably.

Most absorbent pads are made from cellulose filters. The material should be selected on the basis of thickness, compressibility, manufacturability, and, most of all, uniformity of bed volume. Once an absorbent material has been chosen, optimizing the overall volume absorbed by the test strip is best managed by changing the dimensions (usually the length) of the absorbent pad.

Specifying the Absorbent Pad

All of the specifications for the sample pad apply to the absorbent pad, with the exception of extractables.

Yes! I am InterestedRequest A Callback

Sample Release Pad Sheet / Roll

Sample Release Pad Sheet / Roll
Get Best Quote
Product Price: Rs 1 / PieceGet Best Price

Product Brochure

Product Details:
GSM80 GSM
Ply2 Ply
MaterialCardboard
BrandPrahas
Usage/ApplicationHospital
ColorWhite
Country of OriginMade in India

Description

Product Sample Release Pad
Catalog PRHRMC013
Material Polyster
Type Roll/Sheet
Appearance White
Dimension  Width Customised
Length Customised / 100 Mtr
Thickness(mm) 0.30 -0.50
Porosity (Sec) 5 -7
Wicking Time (S/4 cm) 67
Sheet / Roll Sheet , Roll


Additional Information:

  • Delivery Time: 7 Days
Yes! I am InterestedRequest A Callback

Nitrocellulose Membrane For Lateral Flow Immunoassay

Nitrocellulose Membrane For Lateral Flow Immunoassay
Get Best Quote
Product Price: Rs 70 / PieceGet Best Price

Product Brochure

Product Details:
ICMR ApprovedYes
Tests KitWHOLE BLOOD TEST,INFECTION DISEASE,OVULATION MONITORING,DENGUE
Usage/ApplicationClinical
MaterialPlastic
Length100MM
Breadth20mm
ColorWHITE

Nitrocellulose membrane is a very critical component of the assey. Along with high protein binding, surface quality and performance consistency and crucial parameters of substrate quality.
variation in capillary flow rate and thikness across strip will be detrimental to a assey''s sensitivity, reproducibility and reagent consumptions. in case of uneven fiber distribution or nitrocellulose powder settlements on the surface, the protein binding ability of the membrane wiil be compromised. Further, variations in the mentioned parameters across batches can create issues of manufacturing in process approvals and final assey performance.
we provides consistent, reliable membrane with best surface quality and performance consistency to improve your assey.
strong in house capabilites including customised casting machines, large batch size, proprietary processes,strict process controls and stringent product testing standards enable us to provide yu the membrane which is consistent in physical and chemical properties..
THE DEVICE IS SUITABLE FOR:
1. INFECTION DISEASE 
2. WHOLE BLOOD TEST 
3. OVULATION MONITORING 
4. DENGUE



Additional Information:

  • Item Code: PHC100
  • Packaging Details: AS PER YOU REQUIRED
Yes! I am InterestedRequest A Callback

EXPLORE MORE CATEGORIES

© Prahas Healthcare LLP. All Rights Reserved (Terms of Use)Developed and managed by IndiaMART InterMESH Ltd.